The Control4 driver detects the XR150/XR550 panel with Control4's Simple Device Discovery Protocol (SDDP) broadcast. When the Control4 Composer V2.8 or greater sees the XR panels SDDP broadcast, it asks if you want to integrate the DMP XR panel that is on your network. This makes the integration seamless, easy to detect, and inexpensive.

Designed to remain generic and flexible, this driver gives dealers greater control over the security system. Arm or disarm the system and receive full zone status. The driver also allows for custom user codes defined inside Composer.

The position of the indicators on the loop-based device front panel are shown in the Figure 2B: Figure 2B Loop-based device front panel Reset Disabled state. Figure 3 Front panel push buttons Used to reset the FAAST LT device from alarm (requires pass-code access). Also resets the device from a simulated alarm in the. DRIVER OVERVIEW-This driver integrates a DMP XR550 or XR150 security panel into your Control4 project. Composer version 2.8 or greater is required for this driver. Please follow the setup below to use this driver with the panel. The driver is limited to a maximum of eight areas, but is unlimited to the number of zones and outputs. Intel® Integrated Sensor Solution Utilities Tool for Intel Atom® Processor E3900 Series, Intel® Celeron® Processor N3350, and Intel® Pentium® Processor N4200 for Yocto Project. Version: MR3.1 (Latest) Date: 8/7/2017.

Features

  • 2.8 Alarm Proxy
  • Arm/Disarm individual areas (Does not support Home/Sleep/Away or All/Perimeter)
  • Track zone status for each area
  • Define user codes for each area (30 users per area)
  • Set individual areas to bypass/force zones on arm
  • Receive user disarmed events for use in Control4 programming:
    • User 1 Disarmed - Turn lights on in User 1's office

DRIVER OVERVIEW
-------------------------------------------------------------------------------------------

This driver integrates a DMP XR550 or XR150 security panel into your Control4 project. Composer version 2.8 or greater is required for this driver. Please follow the setup below to use this driver with the panel. The driver is limited to a maximum of eight areas, but is unlimited to the number of zones and outputs.

**NOTE: The keypad is featured with a six-character buffer limit that is cleared after 20 seconds of inactivity. This is intended for arming and disarming functionality. If the keypad is empty, and a user tries to arm or disarm the system, a keypad will pop up requesting a code.

DMP HARDWARE AND SOFTWARE SETUP
-------------------------------------------------------------------------------------------

A DMP installer is recommended for this part of the setup.
Physical wiring and configuration of the panel are required for operation as well as configuration through the Remote Link software for setting up areas, zones, outputs, and other panel information.
For real-time feedback for area status, zone status, and output status, configuration for the Entré Connection must be done as well as enabling real-time status for zones and outputs.
For emergency setup, outputs must be assigned to fire, medical, panic, and police.


COMPOSER SETUP
-------------------------------------------------------------------------------------------

1. Add the DMP Security Panel driver to the project.

2. Enter the security panel’s network address in the Connections tab.

3. Set the account number and the remote key in the properties tab. For
details on those properties, see documentation below.

4 At this point, the panel should be connected and authenticated. If the driver has not
already gotten the information from the panel, click on the Read From Panel button to
retrieve the panel configuration. This retrieval includes areas, zones, system info, outputs,
user codes, and profiles.

5. After the driver successfully reads from the panel, any initial zones or outputs will be
created in the Connections tab for you. If any zones or outputs are added to the panel at any time after,
just click the Read From Panel button again to retrieve those updates.

6. Bind up any connections and then refresh navigators.


PROPERTIES
------------------------------------------------------------------------------------------- Unika driver download for windows 10.

Status: Current network status of the security panel

Mac Address: Mac address of the security panel

Serial Number: Serial number of the security panel

Model Number: Model number of the security panel

Software Version: Software version of the security panel

System Sensor Port Devices Driver Download Windows 10

Account Number: Account number given to the security panel for authorization. Must be a five-character long account number.

Remote Key: Remote key given to the security panel for authorization. Must be an eight-character long key.

Auto Bypass Bad Zones: Automatically bypasses zones that are faulted during an arm or disarm

Auto Force Bad Zones: Automatically forces zones that are faulted during an arm or disarm.

Entry And Exit Delay: Delay, in seconds, for arming and disarming the system.

Relay Mode: Mode to set the output devices of the panel.

Emergency Fire Relay Number: Output number to set on the panel for this emergency. When this emergency is triggered on the UI, it will pulse the specified output number.

Emergency Medical Relay Number: Output number to set on the panel for this emergency. When this emergency is triggered on the UI, it will pulse the specified output number.

Emergency Police Relay Number: Output number to set on the panel for this emergency. When this emergency is triggered on the UI, it will pulse the specified output number.

Emergency Panic Relay Number: Output number to set on the panel for this emergency. When this emergency is triggered on the UI, it will pulse the specified output number.

Entrée IP: IP Address of the Controller used for the Entrée Connection IP Address field in the Remote Link programming software to provide live feedback to the driver.

Entré Last Check In: Timestamp of the last known check in from the Entrée connection. This check in interval is set from remote link remote options.

Entré Outbound TCP Port: Port assigned to the Entrée Connection section of programming
on Remote Link to provide live feedback to the driver.

DEBUG MODE: Used for printing and logging debugging messages.


ACTIONS
-------------------------------------------------------------------------------------------

Reset Bypass Zone: Resets a specific zone back to its original non-bypassable state

Bypass Zone: Sets a specific zone to be bypassed during arming and disarming

Refresh Zones: Retrieves the zone information from the panel

Refresh Areas: Retrieves the area information from the panel

System Sensor Port Devices Driver Download

Refresh Outputs: Retrieves the output information from the panel

Refresh System: Retrieves all pieces of information

Download User Profiles: Retrieves the user profiles from the panel

Download User Codes: Retrieves the user codes from the panel


COMMANDS
-------------------------------------------------------------------------------------------

Sensor Reset – Resets master sensor on panel

Refresh System – Gets latest information from system

System sensor port devices driver download windows 7

Arm All – Arms all available areas

Disarm All – Disarms all available areas


EVENTS
-------------------------------------------------------------------------------------------

Trouble Start

Trouble Clear

Armed

Disarmed

Arm Failed

Disarm Failed

Alarm

Alarm Clear

Partition State Changed

Emergency Triggered

WATCHDOG: Control4 variable and event that changes every time the network status changes. The variable gets set to true when the panel is online and false when the panel is offline.

LAST_VALID_CODE_ENTERED_NUMBER: Control4 number variable and event that changes every time someone enters a valid user code for arming the system.

LAST_VALID_CODE_ENTERED_STRING: Control4 string variable and event that changes every time someone enters a valid user code for arming the system. Seccsd laptops & desktops driver downloads.

System Sensor Port Devices Driver Download


CONNECTIONS
-------------------------------------------------------------------------------------------

Panel

Dynamic Zone Connections

System sensor port devices driver download pc

Dynamic Output Connections

Partition

System Sensor Port Devices Driver Download 32-bit